Smart Managed Ethernet switch with 14 10/100BaseT(X) ports, 2 10/100/1000BaseT(X) ports, and -40 to 75C operating temperature, dual power supply 12/24/48 VDC

Ethernet

Total Ethernet 16
10/100 Mbit/s 14
Type 10/100 Mbit/s 14xRJ-45
10/100/1000 Mbit/s 2
Type 10/100/1000 Mbit/s 2xRJ-45

Switch Properties

Managed Yes
Switch Level Layer 2
Supported functions Port Mirror, Port Lock, Broadcast Storm Protection, Flow Control, Back pressure flow control, Security features based on IEC 62443
MAC Table Size 8000
Packet Buffer Size 3 kBit
Max. Number of VLANs 8

Supported Protocols

Industrial Protocols EtherNet/IP, PROFINET, Modbus TCP
Managment Protocols NTP Server/Client, SNTP, SNMP Inform, SNMPv1/v2c/v3, LLDP, Syslog, VLAN
Reservation protocols STP, RSTP
Security Protocols HTTPS
IEEE Standard IEEE 802.1D-2004 for Spanning Tree Protocol, IEEE 802.1P for Class of Service, IEEE 802.1Q for VLAN Tagging, IEEE 802.1W for Rapid Spanning Tree Protocol, IEEE 802.3 for 10BaseT, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3u for 100BaseT(X) and 100BaseFX, IEEE 802.3x for Flow Control, IEEE 802.3z for 1000BaseSX/LX/LHX/ZX

Digital Input

Total channels of digital input 1
Type Wet contact
Level of Logic "0" -30~3 V
Level of Logic "1" 13~30 V

Digital Output

Total channels of digital output 1
Type Signal Relay
Contact rating of relay (Form A) 1A@24V DC

LED / Controls

Setup of Operation Mode Web-interface, ABC-configurator

Connectors

Connectors USB type A

System Power Input

Redundant power input Yes
Input Voltage DC Min 9.6 V
Input Voltage DC Max 60 V
Power Supply Reserve input Voltage DC Min 9.6 V
Power Supply Reserve input Voltage DC Max 60 V

Construction

Construction Chassis Metal Chassis
Mounting Configuration DIN-Rail mount
Protection Level of Chassis IP40

Dimensions and weight

Width 36 mm
Depth 111 mm
Height 135 mm

Operating Conditions

Operating Temperature Min -40 °C
Operating Temperature Max 75 °C

Standards and Certifications

EMI FCC Part 15 Subpart B Class A, CISPR 32
EMS IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, EN 61000-6-2, EN 61000-6-4
Safety UL 61010-2-201, EN 62368-1 (LVD)
Freefall IEC 60068-2-32
Vibration And Shock IEC 60068-2-6, IEC 60068-2-27