Перейти до вмісту

SICOM3024GS-L3G-4X12GX12GP-H3-H3

Ціна за запитом
Industrial 28-port managed L3 PoE switch, IEEE 1588, 12 PoE ports 10/100/1000Base-T(X), 12 slots 100/1000Base-X SFP, 4 slots 10GBase-X SFP+, redundant power 100-240VAC/110-220VDC(85-264VAC/77-300VDC), IP40, -40...+75C

Specification

Ethernet

Total Ethernet28
10/100/1000 Mbit/s12
Type 10/100/1000 Mbit/s12xRJ45
SFP 100/1000 Mbit Ports12
10 Gbit SFP+ Ports4
PoE 10/100/1000 Mbit/s12
Power Budget240 W

Switch Properties

ManagedYes
Switch LevelLayer 3
Supported functionsLoop Protection
MAC Table Size16000
Packet Buffer Size32000 kBit
Jumbo Frame Size9.6 kB
Max. Number of VLANs4000
Priority Queues8
IGMP Groups256

Supported Protocols

Protocol Layer 3Static Routing, RIP V1/V2, OSPF, PIM-SM, PIM-DM
Managment ProtocolsVLAN, PVLAN, GVRP, LACP, SNMPv1/v2c/v3, QoS, SFTP, HTTP, RMON, Syslog, LLDP, DHCP, ARP
Reservation protocolsDT Ring, DT Ring+, DT VLAN, DRP/DHP, STP, RSTP, MSTP
Security ProtocolsACL, RADIUS, TACACS+, IEEE 802.1X Network Access Control, SSH, HTTPS, SSL, NAT
IEEE Standardieee_802.3i, ieee_802.3u, ieee_802.3ab, ieee_802.3z, ieee_802.3ad, ieee_802.3ae, ieee_802.3x, ieee_802.1p, ieee_802.1q, ieee_802.1w, ieee_802.1s, ieee_802.1x, ieee_802.3at, ieee_802.3af

High-precision time

Time synchronisationIEEE 1588 PTPv2 (HW), SNTP Client, NTP Client

LED / Controls

Setup of Operation ModeTelnet, Console Port, Web-interface

Connectors

ConnectorsConsole Port RS-232 (RJ-45)

System Power Input

Redundant power inputYes
Input Voltage DC77...300 V
Input Voltage AC85...264 V

Construction

Construction ChassisMetal Chassis
Mounting Configuration19" Rackmount
Protection Level of ChassisIP40

Dimensions and weight

Width483 mm
Depth44 mm
Height356 mm

Operating Conditions

Operating Temperature-40...75 °C
Humidity5-95%
MTBF300000 h

Standards and Certifications

CertificationsCE, FCC
EMIfcc_cfr47_part_15, en55022-cispr22_class_a
EMSIEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6
FreefallIEC 60068-2-32
Vibration And ShockIEC 60068-2-6, IEC 60068-2-27