Перейти до вмісту

SICOM3028GPT-L2FT-MB-HV-HV

Ціна за запитом
28 ports Layer 2 managed rack mountable modular switch, 4G+24F ports L2 Chassis with time synchronization, IP40, redundant power 85-264VAC/77-300VDC, IEC61850, IEEE1588, -40...+85C

Specification

Ethernet

Total Ethernet28
10/100 Mbit/s24
10/100/1000 Mbit/s4
SFP Fast Ethernet 100 Mbit/s24
SFP 100/1000 Mbit Ports4

Switch Properties

ManagedYes
Switch LevelLayer 2
Supported technologiesDT-Ring, DT-Ring+, DRP-DHP, QoS
Supported functionsitu-t-g-8261/g.8262
MAC Table Size16000
Packet Buffer Size8000 kBit
Jumbo Frame Size10 kB
Max. Number of VLANs4000
Priority Queues8
IGMP Groups256

Supported Protocols

Industrial ProtocolsIEC61850 MMS server
Managment ProtocolsDHCP Server/Client, HTTP, LLDP, Syslog, Telnet, VLAN, PVLAN, QoS, DHCP, NTP, SNTP, RMON, IGMP, LACP, GMRP, MMS, Multicast, BootP, SNMPv1/v2c/v3, IEEE 1588 PTP V2 (hardware-based)
Reservation protocolsSTP, RSTP, STP, DT Ring, DT Ring+, DT VLAN, DRP/DHP, MSTP
Security ProtocolsHTTPS, RADIUS, SSL, TACACS+, ACL, SSH
IEEE Standardieee_802.3i, ieee_802.3u, ieee_802.3ab, ieee_802.3z, ieee_802.3ad, ieee_802.3x, ieee_802.1p, ieee_802.1w, ieee_802.1s, ieee_802.1x, ieee1588-2008

Expansion Module

Quantity of Slots7
Supported ModuleSM6.6

LED / Controls

Setup of Operation ModeTelnet, Console Port, Web-interface

Connectors

ConnectorsRJ45 (Console), Console Port Mini USB

System Power Input

Redundant power inputYes
Input Voltage DC110...220 V
Power Supply Reserve input Voltage DC110...220 V
Input Voltage AC100...240 V
Power Supply Reserve input Voltage AC100...240 V

Construction

Construction ChassisMetal Chassis
Mounting Configuration19" Rackmount
Protection Level of ChassisIP40
Height44 U

Dimensions and weight

Width482.6 mm
Depth359.7 mm
Height44 mm

Operating Conditions

Operating Temperature-40...85 °C
Humidity5-95%
MTBF359000 h

Standards and Certifications

CertificationsCE, FCC, kema, nema-ts2, en50155/50121
EMIen55022-cispr22_class_a, fcc_cfr47_part_15
EMSIEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-9, IEC 61000-4-10, IEC 61000-4-12, IEC 61000-4-16
Power AutomationIEEE 1613, IEC 61850-3
Safetyul61010
FreefallIEC 60068-2-32
Vibration And ShockIEC 60068-2-6, IEC 60068-2-27