Ethernet |
Total Ethernet | 8 |
10/100/1000 Mbit/s | 8 |
Type 10/100/1000 Mbit/s | 8xM12, 4xM12 (Bypass) |
Switch Properties |
Managed | Yes, Router |
Switch Level | Layer 3 |
Supported functions | Port Lock, Broadcast Storm Protection, Link Aggregation, Automatic power failure notification, Automatic port failure notification, Back pressure flow control, Supports network management system |
MAC Table Size | 16000 |
Max. Number of VLANs | 32 |
IGMP Groups | 1024 |
Supported Protocols |
Protocol Layer 3 | VRRP, Static Routing, RIP V1/V2, OSPF |
Managment Protocols | IGMPv1/v2, NTP Server/Client, SNTP, SMTP, SNMP Inform, SNMPv1/v2c/v3, HTTP, LLDP, RARP, Syslog, Telnet, TFTP, QoS, DHCP, SNMP, CoS, DHCP Option 66/67/82, DHCP Client, DHCP Server |
Reservation protocols | STP, RSTP, Turbo Ring |
Security Protocols | NAT, HTTPS, SSH, TACACS+, RADIUS, L2TP, IPSec, IEEE 802.1X Network Access Control |
IEEE Standard | IEEE 802.1D-2004 for Spanning Tree Protocol, IEEE 802.1P for Class of Service, IEEE 802.1Q for VLAN Tagging, IEEE 802.1W for Rapid Spanning Tree Protocol, IEEE 802.3 for 10BaseT, IEEE 802.3ad for Port Trunk with LACP, IEEE 802.3x for Flow Control, IEEE 802.3u for 100BaseT(X) |
LED / Controls |
Setup of Operation Mode | Telnet, Console Port, Web-interface, Command Line Interface (CLI), Through MXconfig Utility |
Connectors |
Connectors | Console Port M12 |
System Power Input |
Redundant power input | Yes |
Input Voltage DC | 16.8...137.5 V |
Power Supply Reserve input Voltage DC | 16.8...137.5 V |
Construction |
Construction Chassis | Metal Chassis |
Mounting Configuration | Wall |
Protection Level of Chassis | IP40 |
Dimensions and weight |
Width | 160 mm |
Depth | 70 mm |
Height | 115 mm |
Operating Conditions |
Operating Temperature | -40...70 °C |
MTBF | 795840 h |
Standards and Certifications |
EMI | CISPR 32, FCC Part 15 Subpart B Class A |
EMS | IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, EN 55024, EN 55032, EN 55035 |
Rolling Stock | EN 50121-4, EN 50155, IEC 60571, EN 45545-2 |
Safety | IEC 60950-1, UL 61010-2-201 |
Freefall | IEC 60068-2-31 |
Vibration And Shock | IEC 60068-2-27, IEC 60068-2-64, IEC 61373 |